Oxi700 BOD System
|
Item Number: LS-1601678
|
Oxi700 BOD SystemThe Oxi700 is a 6 sample system that takes precise measurements of BOD based on the manometric principle.
Manometric respirometers relate oxygen uptake to the change in pressure caused by oxygen consumption while maintaining a constant volume.
BOD – Biochemical Oxygen Demand – is an expression for the quantity of oxygen required for biological degradation of organic matter in a waste water sample. BOD Measurement is used for the detection of biologically degradable organic matter in water. The difference between BOD and COD (chemical oxygen demand) is that COD also measures biologically non-degradable organic matter.
Catlog # | Description | Price | LS-1601678 | Control unit with batteries, inductive stirring system with power supply, 6 each of the sensor heads, sample bottles, rubber gaskets, magnetic stirring rods, 1 overflow flask (157 ml), 1 overflow flask (428 ml), one bottle each (50 ml) of the Potassium Hydroxide Solution and Nitirfication Inhibitor and serial cable. | Click Above |
Measuring Principle: | - Manometric
- Mercury-free
- Electronic Pressure Sensor
| Ranges: | - 0 – 40 mg/L
- 0 – 80 mg/L
- 0 – 200 mg/L
- 0 – 400 mg/L
- 0 – 800 mg/L
- 0 – 2000 mg/L
- 0 – 4000 mg/L
| | | Accuracy: | 0.5% full scale at 20°C | | | Applications: | | Result Display: | - BOD in mg/L
- up to 4 digits
- 7 segment LED
| Measurement Display: | - BOD Range
- Sample Volume
- Measurement Duration
- Time of sample reading
| Measurement Period: | User selectable – between 1 and 28 days | | | Automatic Result Storage: | Up to 28 results | | | Storage Interval: | - 1 Day Measurement: hourly
- 2 Day Measurement: every 2 hours
- 3-28 Day Measurement: once daily
| | | Automatic Start: | After temperature equalization of samples | | | Power Supply: | 3 alkaline-manganese batteries (sixe C) | | | Electrical Compliance: | 115/230V, 50-60 Hz | | | Battery Life: | 1 year (“normal” use as BOD5 meter); early warning before battery fails | | | Interface: | RS232 for printer or PC connection | | | Clock: | Real-time clock | | | Protection: | IP 54 (sensor head) | | | Dimensions: | 14.63 x 7.67 x 9.05 inches | | | Weight: | Control Unit w/ Batteries: 8.5 lbs Complete w/ Stirring Unit: 12.68 lbs | | | Housing: | ABS | | | Compliance: | CE | Product Literature | Oxi700 Data Sheet.pdf | Oxi700 Manual | Oxi700 Manual.pdf |
Accessories | | | Description | | Part Number | | | | Sensor Head | | L2444430 | | | | Sample Bottle | Brown Glass, 500 ml | L418644 | | | | Set of Sample Bottles | 6 Pack | L418645 | | | | Serial Cable | | L2444440 | | | | Inductive Stirring System | For 6 Samples | L2444451 | | | | Stirring Rod | | L418637 | | | | Stirring Rod Remover | | L418638 | | | | Rubber Gasket | | L418636 | | | | Overflow Flask | 21.7 ml | L418654 | | | | Overflow Flask | 56 ml | L418655 | | | | Overflow Flask | 94 ml | L418656 | | | | Overflow Flask | 157 ml | L418657 | | | | Overflow Flask | 244 ml | L418658 | | | | Overflow Flask | 360 ml | L418659 | | | | Overflow Flask | 428 ml | L418660 | | | | Set of Overflow Flasks | Contains 7 Flasks | L418654 | | | | Potassium Hyroxide Solution, 45% | 50 ml | L2418634 | | | | Nitrification Inhibitor (N-ATH) | 50 ml | L2418642 | | | | BOD CM Test Tablets | 8 Tablets | L418328 |
|